Inductive Electronic Water Ruler
The inductive electronic water ruler SCSW02 uses advanced technology and features anti-corrosive naval copper contacts, stainless steel protective casing, and high-performance sealing materials for special treatment inside. The product is frost-resistant, heat-resistant, anti-aging, lightning-proof, and immune to electromagnetic interference. It can be used for water level measurement in places such as road waterlogging, rivers, lakes, reservoirs, hydropower stations, irrigation areas, water plants, wastewater treatment plants, and tunnels with accumulated water.
1、
Parameters | Performance | Note |
Range | 100cm | Scalable, 0.5 meters per section |
Accuracy | 1cm | |
Supply Voltage | DC12V | |
Output Signal | RS485 | |
Static Current | Static Current: No more than 3mA | |
Operating Temperature | Operating Temperature: -10 to 50 ℃ (no freezing) | |
Relative Humidity | Relative Humidity: No more than 95% |
2、 Structure and Wiring
(1) Water Level Ruler Appearance Structure
The water level ruler adopts a stainless steel shell, anti-corrosion naval brass touch points, and anti-corrosion pressure-resistant water-tight potting. The upper end of the water level ruler is connected to the terminal equipment through RS485.
(2) Water Level Ruler Wiring Definition
The cable of the water level ruler is drawn from the upper end of the ruler. The line definition includes power lines and 485 communication lines. The color definition of the wiring is as follows:
No. | Wire Color | define | Note |
1 | Shielded Wire | EARTH | Connected to terminal ground |
2 | Red | +12V | Power supply end |
3 | Black | GND | Reference ground |
4 | White | A | RS485 signal A |
5 | Green | B | RS485 signal B |
3、 Installation
Depending on the application environment, the water level gauge adopts different installation methods:
(1)Flange fixed installation on the ground for roads
(2) U-shaped hoop connector fixed on the wall for dams or places close to the wall